COLTON HEATING & COOLING
  • 315 E. Elm St. Wheaton, IL 60189

Why Should I Demand a CO Test?

Carbon Monoxide is the #1 cause of poisonings in the U.S. Yet less than 5% of all CO Poisonings are reported! The safe and efficient operation of your heating equipment and other combustion appliances cannot be determined without testing using a calibrated combustion analyzer. Because the technology, instruments and training to do this testing correctly has only been available for a few years, odds are it’s never been done. Your service technician should be certified to properly test and diagnose potential CO exposure.

It’s About Your Health, Safety and Comfort Carbon monoxide, even in small quantities can cause serious health problems, particularly in children and the elderly. Millions of unsuspecting homeowners are exposed to low levels of CO and don’t even know it. Unfortunately U.L. Listed CO alarms don’t go off until your family has been exposed to 70 ppm (parts per million) for over 3-1/2 hours! Most international limits for unsafe levels, including OSHA and the World Health Organization’s guidelines are between at 15-35 ppm. Carbon monoxide can come from additional sources in your home besides your heating equipment, and they should be checked. These sources include your Water Heater, Gas Range, Gas Logs, Space Heater, Boiler – even an attached garage.

Anytime equipment is installed, it’s being exposed to conditions in which it has never been tested to perform. Venting systems, combustion air, duct systems, additional appliances in the building, building pressure etc. They Measure If CO testing is part of your Contractor’s normal protocols he will advise you of this prior to servicing or installing equipment. Odds are when the tech walks into you house he’ll be carrying some type of CO Monitor to immediately check if unsafe CO levels are present. When working on the equipment, he will likely drill a hole in the flue of the appliance, and insert the probe of an electronic combustion analyzer to check actual burner performance. Additional performance testing might require holes to be drilled into the ductwork as well. Once he’s finished testing he should provide documentation and review his results with you.

Frequently Asked Questions

ANSWER: If you purchased your alarm from a store, it will usually only warn you of a life threatening condition. If you read the fine print on the product’s UL listing, you’ll find it offers little protection for children, the elderly, or persons with existing illnesses or CO sensitivity.

ANSWER: According to the World Health Organization, 15-20 ppm is the first level of CO that can affect us. Levels as low as 30 ppm have been discovered to cause heart problems. Store CO alarms do not have to activate until they see 70 ppm for 3-1/2 hours!

ANSWER: According to the World Health Organization, 15-20 ppm is the first level of CO that can affect us. Levels as low as 30 ppm have been discovered to cause heart problems. Store CO alarms do not have to activate until they see 70 ppm for 3-1/2 hours!

ANSWER: Would you call the gas station if you had a problem with your car? Gas companies are well versed in fuel leaks, but their main business is not appliance service and few of them are Certified CO/Combustion Analysts.

ANSWER: You can ask to see his NCI wallet card, plus you will recognize his level of expertise and ability to explain to you what he is doing.

As a consumer you should expect your contractor to be trained in current technology that makes sure you’re heating system is safe, comfortable and efficient. These are probably things you may expect are mandatory, but unfortunately they’re not. The number one benefit of having an NCI Certified CO/Combustion Analyst test your home and appliances for carbon monoxide is his extensive training and knowledge. Your contractor should be trained to measure the safety and efficiency of all your combustion equipment, even appliances that he doesn’t normally sell or service. Thorough testing can also verify that your equipment is operating at peak efficiency and provide the lowest operating costs. Finally, he should provide you with documentation that explains what he has found and what corrections have been or need to be performed. He should also provide you with material to better educate you about carbon monoxide sources and health effects.